Overview
Product overview
Read full descriptionShow less
Special length
- · Significantly improves bubble resistance
If air bubbles are mixed in the liquid, it will hinder the propagation of ultrasonic waves, making the flow measurement unstable. The product successfully improves the stability of flow measurement by making the flow measurement part into a linear structure.
- · Low pressure loss
Since it is a straight pipe, there is almost no pressure loss, reducing the pressure drop in the pipe.
- Saves Space
Save space with integrated detectors and converters.
- Compliant standard
EMC:EN61326-1:2013
RoHS Compliance
Main Specification
| Measure objects | Water |
|---|---|
| Flow range | 0to8000ml/min |
| Fluid temperature | 10~80℃ (ambient temperature0~50℃) |
| Fluid pressure | 0to0.5MPa |
| Process connection | 3/8"PFA tube end (Overall dimension... φ9.53, Inner diameter dimension... φ6.35) |
| Measurement Accuracy | ±2% RD (1700mL/min or more) ±34mL/min (less than1700mL/min) (However, when pouring water at20°C) |
| Cable | Multi-core dedicated cable5m (standard) |
| composite body | IP65(indoor specification) |
Features
- Tokyo Instrumented Flowmeter UCF006
Please provide the complete model, quantity, application and operating conditions so we can check the requirement against the product documentation.
Specifications & Models
Specifications
Models
| Model | Inquiry |
|---|---|
| UCF006 | Inquire |
Need to confirm UCF006?
The inquiry automatically includes this product, brand, representative model and source page.